RDUP (RUS) PE-89 AL – 150 Pair, 24 AWG Filled Foam Skin Cable 5000ft Black
Solid, Annealed Copper, Sizes 19, 22 and 24 AWG
 Core Construction: |
|
Conductors: | Solid, annealed copper; sizes 19, 221 and 24 AWG |
Insulation: | Dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color coded in accordance with telephone industry standards. |
Twisted Pairs: | Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk. |
Core Assembly: |
25 pairs and less: pairs are assembled together in a single group. More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder. |
Filling Compound: | The entire core assembly in completely filled with ETPR compound, filling the interstices between the pairs and under the core tape. |
Core Wrap: | Non-hygroscopic dielectric tape applied longitudinally with an overlap. |
Sheath: |
|
Aluminum Shield: |
Corrugated, copolymer-coated, 0.008″ aluminum tape applied longitudinally with an overlap. The sheath interfaces are flooded with an adhesive water-blocking compound. |
Jacket: | Black, linear low density polethylene |
 Application(s): |
Intended for duct and direct buried installations where protection against water and moisture entry is required and may also be installed aerially. |
 Compliance: |
Rural Development Utility Program (RDUP) 7CFR 1755.890 (RUS PE-89) RoHS Compliant (effective 1/1/10) |
 Packaging: |
Standard lengths are shipped on non-returnable wood reels. Non-standard packaging is available upon request. |
Coming Soon…
 Nominal Cable Data: |
|
 Pairs: |  150 |
 Size: |  24 AWG. |
 O.D. (Inches): |  1.00 |
 Weight (lb/MFT): |  635 |
 Standard Length (Feet): |  5000 Feet |
 Core Construction: |
|
Conductors: | Solid, annealed copper; sizes 19, 221 and 24 AWG |
Insulation: | Dual insulation consisting of an inner layer of foamed polyolefin surrounded by a solid polyolefin skin, color coded in accordance with telephone industry standards. |
Twisted Pairs: | Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk. |
Core Assembly: |
25 pairs and less: pairs are assembled together in a single group. More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder. |
Filling Compound: | The entire core assembly in completely filled with ETPR compound, filling the interstices between the pairs and under the core tape. |
Core Wrap: | Non-hygroscopic dielectric tape applied longitudinally with an overlap. |
Sheath: |
|
Aluminum Shield: |
Corrugated, copolymer-coated, 0.008″ aluminum tape applied longitudinally with an overlap. The sheath interfaces are flooded with an adhesive water-blocking compound. |
Jacket: | Black, linear low density polethylene |
 Application(s): |
Intended for duct and direct buried installations where protection against water and moisture entry is required and may also be installed aerially. |
 Compliance: |
Rural Development Utility Program (RDUP) 7CFR 1755.890 (RUS PE-89) RoHS Compliant (effective 1/1/10) |
 Packaging: |
Standard lengths are shipped on non-returnable wood reels. Non-standard packaging is available upon request. |